Communication ports to use the Kentix360 Cloud 2015-10-26T09:51:23+00:00

 

To connect your AlarmManager with the Kentix360 cloud the creation of a customer account is required in the first step. This registration is done via the Kentix ControlCenter and requires a connection to the Kentix cloud server “mykentix.com” on TCP port 443 (SSL secure connection).

To connect the AlarmManager with the Kentix360 cloud also TCP port 5222 between AlarmManager and the cloud server “mykentix.com” must be available. This must eventually be considered in the configuration of your network.

HowTo use the Kentix App with Windows Phone 2015-10-23T09:30:21+00:00

With the Microsoft Developer Kit there is now a possibility to use Android Apps on a Windows Phone.
A description and list of the supported Windows-Phones can be found on Neowin.

The latest APK-Installer for the Kentix-App can be downloaded here.

Kentix App for Blackberry 2015-10-23T09:31:47+00:00

With firmware version 10.2.1 BlackBerry released a new update, which includes a second operating system with Android 4.2.2. This provides support for Android apps and hence the support for the Kentix App.

Download Kentix APK Installer for BlackBerry

Further information on the topic Android app on BlackBerry on AndroidAuthority

AXIS IP Kamera triggering (axis.com) 2015-07-21T11:57:31+00:00

How to trigger an AXIS IP-Camera with the AlarmManager to transmit pictures in case of an alarm.

Download PDF

Kaba B-NET: Integrate access control (kaba.de) 2015-07-21T11:58:14+00:00

How to integrate a KABA B-NET 9250/9290 access control in a Kentix alarm system.

Download PDF

MultiSensor-LAN / -Rack sends no E-mails 2015-07-21T11:58:29+00:00

In standalone-mode the MultiSensor-LAN / -Rack independently sends alarms to the configured users by e-mail.
This requires a valid e-mail account, which has to be entered in the “Configuration” section in the web interface of the MultiSensor.
When the sending of an e-mail fails, there will be a logbook entry showing an error code.
The last 3 digits of the error code give an information on the cause of the unsuccessful e-mail sending.
In most cases the errors are caused by authentication problems – a failed attempt to login to the server, or the user data are invalid – either on the MultiSensor or on the server side.

When having a problem with the sending of e-mails please always check/compare the entered data in the MultiSensor.
Also take care that the encryption type and communication port are set in accordance to the e-mail server.

AlarmManager: No connection with the ControlCenter 2015-07-21T11:58:38+00:00

In case of a connection error in the ControlCenter when trying to access an AlarmManager please check the following points:

  • Please check the entered IP by entering it in the address field of a web-browser.
  • When Dashboard of the AlarmManager does not appear in the browser, then please check whether the IP address is correct.
    You can use the ControlCenter to search for available Kentix devices in the Network by selecting “Update -> Device search…” in the menu bar.
  • If the web interface is available, but a connection via ControlCenter is still not possible, then login to the web interface with your user data and restart the AlarmManager by pressing “Perform restart” in the configuration section.
  • If none of these points leads to a success, then please restart the AlarmManager by disconnecting it from power for approx. 5 seconds. After this try to reconnect with the ControlCenter.
AlarmManager: No measurement values on the AlarmManager-Dashboard after firmware update 2016-11-04T01:34:02+00:00

When performing a firmware update of the AlarmManager, please check on the Kentix website if there are also new firmware versions for you MultiSensors.
We always recommend to update ALL devices together.

If there are still no measurement values after the update of all devices,
then please check, whether the option “AlarmManager communication” is still activated inside the MultiSensor’s web interface, and the correct AlarmManager-IP is specified (MultiSensor-LAN / -LAN-RF / -RACK).
Sollten auch nach dem Update der MultiSensoren keine Messwerte zu sehen sein,
überprüfen Sie zusätzlich ob im Web-Interface des MultiSensors die AlarmManager-Kommunikation noch aktiv und die richtige IP-Adresse des AlarmManagers hinterlegt ist.
Modify these settings if necessary and restart the MultiSensor by clicking the “Save” button.

Leakage sensor triggers no alarms 2015-07-21T11:48:11+00:00

The Kentix leakage sensor KLS03 sends its alarm using the digital input at the AlarmManager or a MultiSensor.

Please note that the alarm assignment of the “System input 1” at AlarmManager or MultiSensor has to be set to “Always-Active” to have an alarm notification.

The setup for the alarm assignment can be done in the ControlCenter in the section “Sensors-Devices” for every MultiSensor separately.

When the leakage sensor is connected to the MultiSensor using a Power-Adapter (KIO1 or KIO3), then please also note that a fully wired patch cable is required for the connection.

Leakage sensor permanently triggers alarms after installation 2016-11-04T01:34:03+00:00

The Kentix leakage sensor KLS03 sends its alarm using the digital input at the AlarmManager or a MultiSensor.
As this input is always in “open state” without having wired an external component,
the leakage sensor will signalize a pending alarm when being connected as it closes this digital input.

To fix this simply log in on the AlarmManager using the Control Center and open the section “Sensors – devices”.
Select the device to which the leakage sensor is connected and change the alarm logic for “System input 1” from “Alarm when – Closed” to “Alarm when – Open”.
Also make sure that the alarm assignment right next is set to “Always-Active”.

Then click “Save” to transfer the configuration changes to the Alarm Manager.
The state of the MultiSensor’s input is now displayed with a green checkmark signaling “OK”.

You can now test the alerting e.g. with a damp cloth.

OPC-Server Intergration (overview) 2016-11-04T01:34:04+00:00

Overview of the requirements for integrating Kentix in a SCADA- or building management system using OPC.

Download

Query measurement values from the Kentix AlarmManager as XML data 2016-11-04T01:34:06+00:00

This article describes how to query measurement values as XML data for further processing.

Download

Kentix MultiSensor-LAN-RF How-To 2016-11-04T01:34:07+00:00

HowTo monitor distributed infrastructure using the MultiSensor-LAN-RF.

Download

IPSWITCH WhatsUpGold (whatsupgold.com): AlarmManager Integration per MIB-file 2016-11-04T01:34:09+00:00

This article describes how to import a Kentix AlarmManager in WhatsUpGold using the MIB-file and how to configure alarm-notifications.

Download

Nagios (nagios.org): AlarmManager import in Nagios and howto for the SMS gateway 2016-11-04T01:34:10+00:00

This article describes how to import a Kentix AlarmManager in Nagios and use the AlarmManager as an SMS gateway out of Nagios.

Download

Download link for the required Perl Scripts:

Download Perl Scripts

ManageEngine OpManager (manageengine.com): AlarmManager MIB import in OpManager 2016-11-04T01:34:12+00:00

This article describes, how to import a Kentix AlarmManager in OpManager using the MIB-file and how alarm-notifications have to be configured.

Download

Paessler – PRTG (paessler.com): AlarmManager MIB import in PRTG and howto for the SMS gateway 2017-01-02T10:11:56+00:00

This article describes how to import a Kentix AlarmManager into PRTG using the AlarmManager MIB-file.
It is also described how the AlarmManager can be used out of PRTG as an SMS Gateway.

Download

The converted OIDLib-files for PRTG can be downloaded via the following link:

Download OIDLibs