Skip to main content
Start your Dual SmartPDU project with a 20% discount with the code KPMDU01-2411
Secure your offer!

Leakage sensor for detecting water and flooding

Sysport (TYPE A)
The leakage sensor is used to detect water leakage on the floor and is connected to an SiteManager or MultiSensor directly to the Kentix system port (TYP A). It continuously detects conductivity via multiple electrodes directly on the housing or additionally via a sensor cable.
The sensor has an integrated point sensor with adjustable sensitivity. The versions with sensor cable (KLS03-ROPE-10/20) detect water in addition to the point sensor over the entire sensor cable length (10/20m). The sensitivity of the point sensor is 1-2ml water, the sensitivity of the sensor cable is approx. 10ml water over 20cm cable length.
The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.

Accessories

Accessories

SiteManager as a hardware appliance for the individual project start
Appliance / Docker KentixONE Sysport (TYPE A) 4G-Modem
  • Up to 500 devices (LAN/RADIO)
  • Detected threats: >40
  • Web-Server (HTTPS) – Smartphone App
  • E-MAIL – PUSH - SMS - VDS2465
  • LDAP - SNMP-V2/3 - REST-API - WEBHOOKS
The Kentix SiteManager is the central management unit for all Kentix installations. It integrates all functional areas such as SmartAccess, SmartMonitoring, SmartPDU and SmartVideo. The SiteManager can manage up to 500 devices from different functional areas and offers the functionality of an alarm center with different transmission paths (network, mobile radio) for alerting. The KentixONE software is already integrated and configuration is conveniently carried out via a web browser.The SiteManager offers flexible installation options, such as top-hat rail mounting on a 35 mm DIN rail or installation in a 19″ IT rack. Power is supplied via an integrated redundancy module with two external power supply units. The SiteManager is therefore the ideal solution for the central control and monitoring of your security infrastructure.Scope of delivery: SiteManager, 19" mounting bracket, 4G magnetic base antenna (2m cable length), plug-in power supply 100-230VAC/24VDC, C14 power supply adapter, KentixONE-SIM Karte (DE/AT/CH)
Design

Price after login

Log in or register now
MultiSensor-LAN with PoE (Black)
KentixONE LAN (PoE) Radio (BLE) Sysport (TYPE A)
  • Integrated sensors: 8
  • Monitored threats: up to 19
  • Web server (HTTPS)
  • E-MAIL - SNMP-V2/3 - REST-API
  • LAN-RADIO (BLE) repeater integrated
Network-compatible MultiSensor for complete room monitoring of up to 19 threats. Monitors an area of approx. 20-25m². The connection is made via Ethernet with PoE (Class 1) and therefore requires no additional cabling. Operation is possible as a stand-alone sensor with integrated KentixONE software (HTTPS) or via a networked KentixONE system with SiteManager. The sensor is mounted on the ceiling using the mounting bracket supplied. Optionally, it can also be mounted in an IT rack or on the wall using the 19’ bracket (accessory).Also ideal as an independent room sensor to supplement network monitoring systems (PRTG, Nagios, CheckMK, etc.) via SNMP-V2/3 or REST-API. The sensor can also send alarm e-mails in stand-alone mode.Integrated sensors: temperature, humidity, dew point, carbon monoxide sensor (CO), 360° PIR motion sensor, 3-axis G-sensor, digital input/outputs.
Color

Price after login

Log in or register now
MultiSensor with Ethernet (PoE) and Thermal-Image
KentixONE LAN (PoE) Radio (BLE) Sysport (TYPE A)
  • Integrated sensors: 9
  • Monitored threats: up to 20
  • 4-factor early fire detection
  • Web server (HTTPS)
  • E-MAIL - SNMP-V2/3 - REST-API
  • LAN-RADIO (BLE) repeater integrated
The MultiSensor-TI is the latest MultiSensor technology with integrated thermal imaging sensor for monitoring critical system conditions and for early fire detection. In addition to pure thermal monitoring, the sensor can also detect the movement of people. Compared to thermal imaging cameras, the sensor has the advantage that it works in compliance with data protection regulations and intelligently links several sensors for early fire detection. For early fire detection, this means that up to four factors (thermal image, CO, air quality, room temperature) are analysed for reliable detection.The MultiSensor monitors up to 20 threats and an area of up to approx. 40m² depending on the ceiling height. It is connected via Ethernet with PoE (Power over Ethernet) and therefore requires no additional cabling. Operation is possible as a stand-alone sensor with integrated KentixONE software (HTTPS) or via a networked KentixONE system with SiteManager. The sensor is mounted on the ceiling using the mounting bracket supplied. Mounting in an IT rack or on the wall with the 19’ bracket (accessory) is also possible as an option.Detection angle: 90° or 40° (depending on type)Integrated sensors for monitoring: Temperature, air humidity, dew point, smouldering fire (CO), air quality, air pressure, movement, acceleration/vibration (G), two external alarm contacts.Alarm notification via MultiSensor (stand-alone): E-mail, SNMP traps (V2/3), web hooks (REsT-API)Alarm notification via SiteManager (central): SMS, PUSH (app)
Field of view
Color

Price after login

Log in or register now

Detect water leakage in server room

Early detection of water leaks in the server room prevents potential damage to expensive IT infrastructure and data loss.

Detect water leakage from dishwasher

Water leakage monitoring for dishwashers protects against water damage and helps avoid unplanned repairs.

Detect water leakage on machine

Water leakage monitoring on machines is used to safeguard production processes and prevent expensive production downtime.

Detect water leakage from pipeline

Monitoring water leaks from pipes minimizes water damage and increases safety in buildings.

Delivery Contents

  • 1 leakage sensor
  • 1 connection cable 10m (patch cable)
  • 1 housing gland for cascading

Specifications

Hi, I'm KAI and I answer all questions about Kentix