MultiSensor with thermal image
Early fire detection with more detection factors and over 50% cheaper than thermal cameras
- 4-Faktor Brandfrüherkennung: Oberflächentemperatur, Kohlenmonoxid (CO), Luftqualität (VOC) und Raumtemperatur
- Integrierter 1024px Wärmebildsensor und 8 weitere Sensoren überwachen über 20 Gefahren
- Einfache Konfiguration über integrierte KentixONE Software
- Integration in andere Systeme über SNMPv2/3, REST-API und Webhooks
- Kostengünstige Alternative zu teuren Wärmebildkameras
- Capteurs intégrés : 9
- Menaces surveillées : jusqu’à 20
- Dètection anticipée des incendies à 4 facteurs
- Serveur Web (HTTPS)
- E-MAIL - SNMP-V2/3 - API REST
- Répéteur LAN-RADIO (BLE) intégré
Le MultiSensor-TI est la toute dernière technologie MultiSensor dotée d’un capteur d’imagerie thermique intégré, destiné à la surveillance des conditions critiques du système et à la Dètection anticipée des incendies. Outre la surveillance thermique proprement dite, le capteur est également capable de détecter les mouvements de personnes. Par rapport aux caméras thermiques, ce capteur présente l’avantage de fonctionner dans le respect des réglementations en matière de protection des données et de relier intelligemment plusieurs capteurs pour la détection anticipée des incendies. Pour la détection anticipée des incendies, cela signifie que jusqu’à quatre facteurs (image thermique, CO, qualité de l’air, température ambiante) sont analysés pour garantir une détection fiable.Le MultiSensor surveille jusqu’à 20 menaces et une surface pouvant atteindre environ 40 m², en fonction de la hauteur sous plafond. Il est connecté via Ethernet avec PoE (Power over Ethernet) et ne nécessite donc aucun câblage supplémentaire. Il peut fonctionner en tant que capteur autonome avec le logiciel KentixONE intégré (HTTPS) ou via un système KentixONE en réseau avec SiteManager. Le capteur se fixe au plafond à l’aide du support de montage fourni. Le montage dans une armoire informatique ou au mur à l’aide du support 19" (accessoire) est également possible en option.Angle de détection : 90°Capteurs intégrés pour la surveillance : température, humidité de l’air, point de rosée, feu couvant (CO), qualité de l’air, pression atmosphérique, mouvement, accélération/vibration (G), deux contacts d’alarme externes.Notification d’alarme via MultiSensor (autonome) : e-mail, traps SNMP (V2/3), webhooks (API REST)Notification d’alarme viaSiteManager (centralisé) : SMS, notifications PUSH (application)
Prix après connexion
Monitored area depending on 40/90° optics and height
The Kentix MulitSensor-TI is mainly used for room and system monitoring with 4-factor early fire detection. The great advantage over thermal cameras is that diffused fire gases are also detected in addition to the surface temperature.One MultiSensor - many applications
Detect fire hazards in battery and accumulator logistics at an early stage
Detect and report electrical defects in IT/OT racks at an early stage
Early detection of fire hazards in company kitchens and kitchens on floors
MONITORING OF USV-BATTERY ROOMS, BATTERY LOGISTICS
4-Factor Early Fire Detection as an alternative to thermal cameras
The MultiSensor-TI is the latest MultiSensor technology and integrates a 1024px thermal image sensor in addition to various gas sensors for monitoring critical plant conditions and early fire detection.
Compared to thermal imaging cameras, the MultiSensor-TI has the advantage that it complies with data protection regulations and links other sensors with the thermal evaluation. For early fire detection, this means that up to four factors (thermal image, CO, air quality, room temperature) are evaluated for reliable detection. The additional fire gas detection (CO, VOC, CO2) offers very significant advantages for very early fire detection.
Integrated Sensors
| Early firedetection | Movement | Climate | Sabotage | Externalalarms | |
|---|---|---|---|---|---|
| Thermal sensor 1024px (40/90°) | |||||
| Carbon monoxide sensor (CO) | |||||
| Air quality (VOC) | |||||
| Temperature | |||||
| Air humidity | |||||
| Dew point | |||||
| Air pressure | |||||
| Vibration | |||||
| External input |
Nos conseils sont uniques. Pourquoi attendre plus longtemps ?
Au cours d'une démonstration en ligne, je vous montrerai à quel point notre solution de sécurité physique s'intègre facilement et en toute sécurité à votre environnement.
Frederik Thom
Key Account Manager Germany North
A success story: Multisensor prevents expensive fire damage at Paket24 (Artelia)
Open blog articleThe MultiSensor saved us from what was probably major damage and failure. It had detected cells in a UPS that had heated up dangerously at an early stage and triggered an alarm. When we looked, everything initially looked normal - it wasn't until we inspected the back panel that the reason for the alarm became clear. If this problem had gone undetected, it could have resulted in a serious fire. But the CO2 sensor on the Kentix multisensor detected the change in carbon dioxide levels early on, before any damage occurred.
Artelia (Paket24)