Dual SmartPDU 19"-2HE with 2x 8/C13 (IEC60320), 16A (A+B) with RCM

KentixONE LAN (PoE) Sysport (TYPE B) MID approved
Dual SmartPDU with separate A+B feed as a system solution with integrated Kentix MultiSensor technology and 2 height units, RCM and calibrated current measurement. The SmartPDU can be easily managed centrally using the integrated KentixONE software. The electronics of the SmartPDU are supplied via PoE, i.e. in the event of a power failure, both the sensors and the management of the PDU are guaranteed by a UPS-buffered PoE switch. In addition, further digital inputs/outputs are available via the Kentix system port, as well as the option of connecting electronic RFID rack levers directly.

Ideal for IT/OT applications
The Dual SmartPDU are two PDUs in one housing and are therefore particularly cost and space-saving. All the advantages of two separate PDUs with separate power supply and intelligent monitoring are retained.

  • 16xC13 IEC60320 IEC-Lock lockable sockets
  • fuse protection 10A per group (C-type)
  • mains connection 2xC20 (A+B) IEC plug
  • measurement with MID approval
  • Accuracy class B (EN50470-3 MID)
  • two counting ranges
  • display illuminated
  • AC/DC differential current measurement (RCM)
  • climate monitoring (Temp/Hum/Dew)
  • 2-factor early fire detection (ΔT/Tmax, VOC)
  • frequency 45-54Hz (0.01Hz)
  • temperature range 0 to 50°C
  • power supply 230/400VAC
  • connected load 4.6KVA
  • power consumption approx. 5W
  • size (LxWxH) 483x88x88mm
  • protection class IP20

Power cords with locking

slide 7 to 9 of 4

Accessories

slide 1 of 1

Monitor UPS for status and fault

UPS system monitoring ensures the functionality of the uninterruptible power supply and protects against data loss during power outages.

Measure and monitor power supply in IT/OT rack

The PDU reliably supplies power to devices in IT racks, monitors key parameters including differential current, and ensures environmental monitoring of the rack

Delivery Contents

  • PDU 2HE ready for connection
Note! Please order the correct power cords

Specifications

Dual SmartPDU 2U, 2×10/16A (up to 2x 3.6kVA) – Datasheet

TypesKPMDU-RC-1600C13C19-2–16-HKPMDU-NC-1600C13C19-1–16-H
Rated power, voltage2×2.3kVA, 230V1×2.3kVA, 230V
Connector plug2x C20 IEC socket (16A) on rear panel1x C20 IEC socket (16A) on rear panel
Connection cableConnection cable must be ordered separatelyConnection cable must be ordered separately
Sockets C13 (IEC60320)16 (2x 8) C13 with A+B supply16 (2x 8) C13 with A+B supply
InterlockIEC-LOCK for C13
Fuse/circuit breaker2x 10A C-type, interlocked
Current measurement (calibrated)Integrated, calibrated current measurement, accuracy Class B (MID, EN 50470-3)
Minimum current 250mA
Residual current measurement (RCM)OPTIONALIntegrated AC/DC
sensitive residual current measurement in accordance with IEC 60664-1
±300mA/100mA (RMS), accuracy <0.2mA
Frequency range DC 0..2kHz
/
ConnectivityEthernet (10/100MBit), PoE Class 3
Kentix system socket (type B)RJ45 with Kentix-specific assignment for system extensions
2 x digital input (e.g. door contacts, leakage detectors, external alarms)
1 x system BUS
Communication and securityHTTPS (certificate), integrated web server, ReSt-API
Port security 802.1x
Protocols: SNMP V2/3 (GET, TRAP), NTP, SMTP, DHCP, MODBUS-TCP
ManagementMain satellite management via KentixONE
Measurement/communication objectsVoltage (V) L1/L2/total
Current (A) L1/L2/total
Consumption (kWh) L1/L2/total
Active power (W) L1/L2/total apparent power (VA) L1/L2/total
Reactive power (VAR) L1/L2/total
Active factor (cos phi)
Frequency (Hz)
Phase monitoring L1/L2/
Residual current AC
Residual current DC
Fuse status L1/L2/
Temperature (°C)
Relative humidity (%)
Dew point (°C)
Vibration (G)
Air quality VOC (AIQ Index)
Display (LCD)Illuminated LCD display (power, current, voltage, consumption)
Optical signalingLED with RED/GREEN (operation, alarm/error status)
Acoustic signalingSignal generator with 80dB, 2.3kHz (alarm/fault conditions)
Factory stateButton for factory reset in side panel
HousingSheet metal, powder-coated RAL9005
Protection class 1, protection rating IP20
Size443 x 88 x 88 mm (WxHxD)
Weightapprox. 3,0kg
Environmental conditions0°C to 60°C, humidity 5-95%
Storage temperature: -20°C to 60°C
CertificationCE (2014/30/EC, 2014/35/EC, 2011/65/EU)
Electrical safetyDGUV V3 testing, VDE 0105-100
MarkingSerial number (barcode)