DoorLock for racks

Network rack handles for almost any rack

IT and OT rack monitoring in your data centre

  • Ergonomic handle designed as a lifting lever in a metal-and-plastic construction; requires no swivel range
  • Connection to SmartPDU (up to 2 handles) or AccessManager (up to 16 handles)
  • The closed and locked status is continuously monitored by a door contact
  • Power supply via PoE enables integration into a UPS power supply
  • Easy management via KentixONE’s integrated web interface

Choosing
an electronic rack handle for IT/OT racks

DoorLock-RA4-IP Rack Handle (MIFARE® DESFire)
DoorLock-RA4-IP Rack Handle (MIFARE® DESFire)
KentixONE LAN (PoE) RFID
  • RFID & PIN
  • LED: RED-GREEN
  • Up to 16 Lifthandles/Ethernetport (PoE)
  • Chassis: Metal-Plastic

IT cabinet handle (left turning) in robust metal-plastic design as folding lever handle. This means that the handle does not require a swivel range and enables ergonomic handling. The connection is made completely via patch cable. Up to 16 handles can be connected per Kentix SmartRelay. Any number of SmartRelays can be networked together. A reed contact can be connected to a distribution box to each IP rack handle to reliably monitor the closing and locking status of the rack door. The power supply is PoE and is therefore easily integrated into the UPS power supply.

Variation
Design

Price after login

Log in or register now

Direction of rotation of the shaft on our lift handles

The KXC-RA4 is available with two shaft rotation directions (right/left). As the lift handle always performs the same movement, the gearbox or shaft rotation must be set to match the door side (L/R).

IMPORTANT! Please ensure you specify the required direction of rotation of the shaft when ordering.

TIP: The direction of rotation is always viewed from the back of the door or the lever. It always corresponds to the side on which the door hinges are located.

KXC-RA4-DIN-RL-1_200x200.png

Select a distribution box for the rack handle in IT/OT racks

Distribution box set for IT rack locking system KXC-RA4 with magnetic contacts
Distribution box set for IT rack locking system KXC-RA4 with magnetic contacts
Sysport (TYPE A)
  • Distribution box for rack levers and door contacts in the rack
  • For connection to AccessManager (ART: KXP-2-RS)
  • 2x rack levers can be connected (ART: KXC-RA4-xxx-x)
  • 2x door contacts can be connected (ART: KDC1-W)

Distribution box with door contacts for cabling and distribution in the rack to two Kentix rack readers (ART: KXC-RA4) and two door contacts. For connection to an AccessManager (ART: KXP-2-RS) via patch/network cable (RJ45)Size (WxLxH): 39x68.5x23.5mm

Price after login

Log in or register now
RFID transponder Key-Fob 4k EV3 (MIFARE® DESFire®)
RFID transponder Key-Fob 4k EV3 (MIFARE® DESFire®)
  • MIFARE®DESFire®
  • RFID key fob Ø36mm
  • Kentix security application
  • Without print

Kentix transponder key fobs are based on MIFARE®DESFire® technology (13.56MHz) type EV3 with 4kB memory. By default, the tokens are written with a special Kentix security application.

Set

Price after login

Log in or register now

What is the distribution box used for?

The distribution box is used to connect the front and rear door components – including the rack handle and door contacts – within the rack. This depends on how the rack handle is connected – either via direct networking of several handles in a bus topology or via connection to a Kentix SmartPDU.

One distribution box is required per cabinet. The rack handle, the door contact and the interconnecting cables are all connected to it. The advantage is that, for eight racks with 16 doors, only one Ethernet port with PoE is required.

Select a mechanical adapter suitable for the rack manufacturer

Mechanical adaptors for various rack manufacturers

The Kentix cabinet lever fits most IT racks without the need for mechanical adjustment, thanks to an adaptor. This is ensured by the standard 50 mm pitch. Some manufacturers design proprietary locking systems. For the most common manufacturers, we offer mechanical adaptors that are simply fitted between the cabinet and the lever. Supported cabinet manufacturers: Rittal, Vertiv (Knürr), Stengel, Schäfer, ZPAS, Modulan and many more. If the type of cabinet you require is not listed, please contact us. We are constantly expanding our list of manufacturers.

Adapters for Rittal TS, TS IT, SE, PC and IW racks

With the Kentix mechanical adapter for Rittal, our rack levers are compatible with Rittal IT and distribution cabinets. Depending on the type, the adapters are suitable for flat standard doors or doors with a slanted design. Variants with door monitoring are available for installation.

Our consulting is unique. Why wait?

In a personal live demo, I will show you how easily and securely our physical security solution can be integrated into your environment.

Colin Clever

Inside Sales Manager
Colin Clever

Kentix locking solutions for IT cabinets

Compared to conventional swivel handles, the Kentix DoorLock-RA4 is a so-called lift lever. The advantage is that the handle allows for space-saving and highly ergonomic operation. Opening the cabinet is very convenient, as the lever springs open automatically and can be opened with a single pull.

Thanks to the standard dimensions used (50 mm grid), the handle is already compatible with many types of rack cabinets. For manufacturers with proprietary lever mechanisms, such as Rittal or Vertiv, corresponding adapter solutions are available to facilitate easy replacement.

In addition to the DoorLock-RA4, we also offer digital half-cylinder locks or radio cabinet locks for simple IT distribution cabinets.

Direct connection of the rack handle to the Kentix SmartPDU

The DoorLock-RA4 is a key system component offering numerous benefits. As well as being used as a Stand-Alone unit, the lever can also be connected directly to a Kentix SmartPDU. This eliminates the need for cabling between the cabinets and ensures that the front and rear door handles of the cabinet are powered redundantly via the PDUs. The SmartPDU manages the handle and monitors the door contacts. The only additional hardware required is a central Access Manager. This makes integration into a comprehensive Kentix locking system even simpler.