Sensors and actuators
Network siren with Ethernet (PoE)
- Network siren with RGB LED
- Multi-tone buzzer up to 100 dB
- As alarm and status indicator
- Own KentixONE presets
- Wall/ceiling mounting
Network alarm siren with PoEThe network-compatible alarm siren can be installed inside the building and in weather-protected outdoor areas. It is a combined signaling device and an essential component of a functioning alarm chain. In the event of an alarm, the siren generates a very loud, adjustable signal tone of up to 100 dB sound pressure. In addition to the acoustic alarm, a visual alarm is given by a colored, clearly visible LED light. It is connected and controlled via an Ethernet PoE network port (RJ45). Product detailsAlarm siren with Ethernet 10/100Mbit for indoor areas, PoE (Class 3), sound pressure: up to 100dB, various sounds adjustable, LED: red/green/blue, temperature range: -20 °C to +70 °C / max. 95%rh, non-condensing, connection: Ethernet RJ45 socket, function: LED colors (RGB) separately controllable, several sound signals to choose from, housing: ABS, IP43, weight: approx. 250g, size: Ø93 mm, H123 mm
The network-compatible alarm siren can be installed both indoors and in weather-protected outdoor areas. It combines audible and visual signals and is a key component of a reliable alarm system.
In the event of an alarm, the siren emits a very loud warning tone, adjustable across several levels, of up to 100 dB. In addition, a highly visible LED light in freely selectable and combinable colours provides a visual warning.
KentixONE offers a wide range of configuration options: freely configurable presets allow you to display your own information, alarm or warning statuses both visually and acoustically.
Connection and control are via Ethernet with PoE through an RJ45 network socket.
Water and liquid sensors with Ethernet (PoE)
- Ethernet leakage sensor with PoE
- Senso sensitivity adjustable
- 2x cable sensor (2x 10m or 20m), 1x chassis sensor
- Auf Kabelbruch überwacht
The leakage sensor is used to detect water leaks on the floor and can be used either as a standalone device or integrated into KentixONE. It continuously measures conductivity via several electrodes directly on the housing and additionally via two 10/20 m long sensor cables.The leakage sensor has 3 separate sensors: One point sensor and two sensor cables that detect water over their entire length (10/20 m). The sensitivity of the point sensor is 1-2 ml of water, and that of the sensor cable is approx. 5 ml of water over a cable length of 20 cm.
The Kentix leakage sensor detects water using a conductive measurement principle: it continuously measures the conductivity between several electrodes. As soon as moisture or water establishes a conductive connection, an alarm is triggered at an early stage.
In addition to the sensor housed in the enclosure, the leak sensor features two sensor cables (10 m or 20 m). These monitor for water ingress along the entire length of the cable. The sensitivity can be adjusted in KentixONE to suit the environment.
Connection is via Ethernet (PoE). The sensor can operate independently and send alarms via email or SNMP v2/v3, or it can be integrated centrally into KentixONE.
I/O expansion modules for alarm connection via Ethernet (PoE)
- 16 digital inputs (for dry contacts)
- connection of external alarm messages
- Integrated web server
- Ethernet 10/100MBit (PoE)
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..16 digital inputs for dry-contacts (e.g. air-conditioning, UPS system, external sensors, etc.)
- 16 digital inputs
- connection of external alarm messages
- Integrated web server
- Power over ethernet (PoE)
The I/O expansion module connects to an SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE.
I/O expansion modules are used to connect external fault and alarm signals via electrical contacts. This makes it easy, for example, to integrate and monitor signals from generators, UPS systems, air-conditioning units, etc. into the KentixONE.
Furthermore, the individual inputs and outputs can be tested via the integrated web server without the need for additional software.
When selecting the appropriate I/O module, it is important to consider the type of signal to be connected. In around 80 per cent of cases, potential-free contacts are used (purely switching contacts without their own voltage). For this purpose, the module with 16 digital inputs (SKU: KIO7053) is the most common and suitable solution. However, live signals (12–50 VDC) and analogue signals (0–10 VDC or 4–20 mA) can also be integrated using the respective modules.
The connection is made via Ethernet (PoE).
Accessories for the I/O expansion modules
- Temperature sensor Pt1000 class B
- 3 selectable temperature ranges
- Protection class IP66
- Integrated sensor
PT1000 class B outdoor temperature sensor with active current (4-20mA) and voltage output (0-10V).Three selectable temperature ranges (-50°C ... + 50°C; 0°C ... + 50°C; 0°C ... +100°C).Housing protection IP66.Power supply 24VDC/4mA.For connection to I/O module KIO7017.
Door contact with open cable. Contact: NO, cable lenght 2 m, color: white, Size: (L x H x W) 11 x 12 x 48 mm, Delivery: Magnet-contact with mounting material
19" mounting frame with 4U for mounting up to 22 modules (Division Units) on DIN rail (35mm), height: 176mm, material: sheet metal 2mm, scope of delivery: 19" frame