Skip to main content
Start your Dual SmartPDU project with a 20% discount with the code KPMDU01-2411
Secure your offer!

Kentix SmartPDU for Data Center
and IT Infrastructure

Achieve high availability of your IT with the Kentix SmartPDU

  • Highest availability with the Kentix SmartPDU
  • Seamless rack monitoring including early fire detection
  • Reliable power supply for IT, OT, edge data centres and large data centres
  • PDU without compromise for critical applications
  • Continuous residual current measurement (RCM) to increase electrical safety and fire protection

SmartPDU functions at a glance

Dual SmartPDU for EDGE and OT applications

Dual SmartPDU 40U with 2x 24/C13 (IEC60320), 2x 32A (A+B) with RCM
KentixONE LAN (PoE) Sysport (TYPE B) MID approved
  • Calibrated dual current measurement (MID)
  • RCM residual current measurement
  • Temperature, humidity, dew point, vibration, early fire detection
  • IEC Lock plug protection
  • RFID rack locking system can be connected directly
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.
Plug-in type
Socket function
Power connection

Price after login

Log in or register now
Dual SmartPDU 19"-2HE with 2x 8/C13 (IEC60320), 16A (A+B) with RCM
KentixONE LAN (PoE) Sysport (TYPE B) MID approved
  • Calibrated dual current measurement (MID)
  • RCM residual current measurement
  • Temperature, humidity, dew point, vibration, early fire detection
  • IEC Lock plug protection
  • RFID rack locking system can be connected directly
Dual SmartPDU with separate A+B feed as a system solution with integrated Kentix MultiSensor technology and 2 height units, RCM and calibrated current measurement. The SmartPDU can be easily managed centrally using the integrated KentixONE software. The electronics of the SmartPDU are supplied via PoE, i.e. in the event of a power failure, both the sensors and the management of the PDU are guaranteed by a UPS-buffered PoE switch. In addition, further digital inputs/outputs are available via the Kentix system port, as well as the option of connecting electronic RFID rack levers directly.Ideal for IT/OT applicationsThe Dual SmartPDU are two PDUs in one housing and are therefore particularly cost and space-saving. All the advantages of two separate PDUs with separate power supply and intelligent monitoring are retained.16xC13 IEC60320 IEC-Lock lockable socketsfuse protection 10A per group (C-type)mains connection 2xC20 (A+B) IEC plugmeasurement with MID approvalAccuracy class B (EN50470-3 MID)two counting ranges display illuminatedAC/DC differential current measurement (RCM)climate monitoring (Temp/Hum/Dew)2-factor early fire detection (ΔT/Tmax, VOC)frequency 45-54Hz (0.01Hz)temperature range 0 to 50°Cpower supply 230/400VACconnected load 4.6KVApower consumption approx. 5Wsize (LxWxH) 483x88x88mmprotection class IP20
Plug-in type
Socket function
Power connection

Price after login

Log in or register now

Dual SmartPDU, two separate PDU in one housing

All-in-one system solution consisting of Dual SmartPDU with separate A+B feed and integrated MultiSensor with 40 height units, RCM and calibrated current measurement. Due to the already integrated KentixONE software and MultiSensor, up to 50 SmartPDUs can be managed without further hardware/software. The electronics are powered by PoE. This means that in the event of a power failure, thanks to a UPS-buffered PoE switch, the sensor technology as well as the management of the PDUs will continue to function. In addition, further functions can be controlled and digital inputs/outputs are available via the Kentix system port.

Ideal for EDGE and OT applications. The Dual SmartPDU is two PDUs in one chassis, making it especially cost- and space-efficient. All the benefits of two separate PDUs with separate power feeds and intelligent monitoring are retained.

SmartPDU for high-availability data center applications

SmartPDU 40U with 24/C13-6/C19 (IEC60320), 3-phase 32A with RCM
KentixONE LAN (PoE) Sysport (TYPE B) MID approved
  • Calibrated dual current measurement (MID)
  • RCM residual current measurement
  • Temperature, humidity, dew point, vibration, early fire detection
  • IEC Lock plug protection
  • RFID rack locking system can be connected directly
Kentix SmartPDUs are system components for the intelligent expansion of your rack infrastructure. All important sensors and interfaces for future-proof operation are already integrated.24xC13 and 6xC19 IEC sockets IEC-Lock lockable (IEC60320)protection 16A per group (C-type)mains connection IEC60309 connector 32A (ROT) (L1/L2/L3/N/PE/6h)cable connection H07RN-F (6mm2)measurement with MID approvalclass B accuracy (EN50470-3 MID)three counting rangesAC/DC differential current measurement (RCM)climate control (Temp. Hum / Dew)Network connection RJ45 (PoE Ethernet)Frequency 45-54Hz (0.01Hz)Temperature range -10 to 50 ° CPower supply 230VACPower consumption 22KVAPower consumption approx. 5WSize (LxWxH) 1770x78.1x62. 5mmprotection class IP20
Plug-in type
Socket function
Power connection

Price after login

Log in or register now
SmartPDU 19"-3HE with 27/C13 (IEC60320), 3-phase 32A with RCM
KentixONE LAN (PoE) Sysport (TYPE B) MID approved
  • Calibrated dual current measurement (MID)
  • RCM residual current measurement
  • Temperature, humidity, dew point, vibration, early fire detection
  • IEC Lock plug protection
  • RFID rack locking system can be connected directly
Material/Color: Sheet metal/black (RAL9005) powder-coated, 27xC13 IEC sockets IEC-Lock lockable (IEC60320), protection 16A per group (C-type), mains connection IEC60309 connector 32A (RED) (L1-3/N/PE/6h), cable connection 3m H05RN-F (6mm2), measurement with MID approval, class B accuracy (EN50470-3 MID), three counting ranges, display illuminated, AC/DC differential current measurement (RCM), climate control (Temp. Hum / Dew), Network connection RJ45 (PoE Ethernet), Frequency 45-54Hz (0.01Hz), Temperature range 0 to 50°C, Power supply 230/400VAC, Power consumption 11KVA, Power consumption approx. 5W, Size (LxWxH) 483x132,5x88mm, protection class IP20, content of delivery: PDU 3HE ready for connection, mounting set
Plug-in type
Socket function
Power connection

Price after login

Log in or register now

Modular SmartPDU for almost all applications

All SmartPDU models are equipped with calibrated current measurement of the most important electricity parameters. This means that the consumption data can also be used in the collocation data centre for legally compliant billing.

The integrated residual current monitoring (RCM) makes it possible to carry out the required electrical device tests in accordance with DGUV-V3 even without switching off and contributes to greater electrical safety and increased fire protection.

The SmartPDUs work according to the main-satellite principle. This means that a main PDU collects all the data from the connected satellite PDUs. In addition, the main PDU can also read an external main power meter via Modbus Ethernet, thus enabling a direct PUE (Power Usage Effectiveness) calculation. This means that one of the most important energy indicators is available in the data centre without external software.

The integrated KentixONE software makes management extremely easy, regardless of whether you have one or a thousand SmartPDUs.

Kentix SmartPDU for a secure power-supply in the Data Center

The software integrates all open interfaces for effective management from a single rack to a large data center. All functions are available in the browser via a modern web GUI. KentixONE is license-free and future updates are available free of charge. New software versions can be easily distributed automatically to all clients via the PDU defined as the "main controller". Thanks to SNMP V2/3 and the SNMP MIB Base, which can be easily downloaded from the PDU, integration into existing monitoring systems is very simple. The comprehensive, event-based REST API with so-called web hooks goes one step further. This makes all PDU functions available in encrypted form via SSL/TLS and offers completely new possibilities for effective data center automation. This makes it easy to distribute configurations or templates and service technicians or colocation customers can be guided visually and acoustically to their racks. KentixONE supports Active Directory or LDAP to simplify user management and control of the SmartPDU or connected electronic rack handles via a central directory server.

SmartPDU as system basis for rack monitoring and access control

The DoorLock-RA4 is an important system component with many advantages. In addition to stand-alone use, the lever can also be connected directly to a Kentix SmartPDU. This eliminates the need for wiring between cabinets and provides redundant power to the cabinet's front and rear door handles via the PDUs. The SmartPDU takes over the management of the handle and the monitoring of the door contacts. Only a central AccessManager is then required as further hardware. Integration into an overall Kentix locking system is thus even more easily solved.

More details

Need more information?

Contact us or get to know our products in an online consultation - free of charge and without obligation, of course.

Miguel Marinho

Inside Sales Manager

Miguel Marinho
Hi, I'm KAI and I answer all questions about Kentix