The MultiSensor-TI is the latest MultiSensor technology with integrated thermal imaging sensor for monitoring critical system conditions and for early fire detection. In addition to pure thermal monitoring, the sensor can also detect the movement of people. Compared to thermal imaging cameras, the sensor has the advantage that it works in compliance with data protection regulations and intelligently links several sensors for early fire detection. For early fire detection, this means that up to four factors (thermal image, CO, air quality, room temperature) are analysed for reliable detection.
The MultiSensor monitors up to 20 threats and an area of up to approx. 40m² depending on the ceiling height. It is connected via Ethernet with PoE (Power over Ethernet) and therefore requires no additional cabling. Operation is possible as a stand-alone sensor with integrated KentixONE software (HTTPS) or via a networked KentixONE system with SiteManager. The sensor is mounted on the ceiling using the mounting bracket supplied. Mounting in an IT rack or on the wall with the 19’ bracket (accessory) is also possible as an option.
- Detection angle: 90° or 40° (depending on type)
- Integrated sensors for monitoring: Temperature, air humidity, dew point, smouldering fire (CO), air quality, air pressure, movement, acceleration/vibration (G), two external alarm contacts.
- Alarm notification via MultiSensor (stand-alone): E-mail, SNMP traps (V2/3), web hooks (REsT-API)
- Alarm notification via SiteManager (central): SMS, PUSH (app)
Extensions
Extensions
MultiSensor with Ethernet (PoE) and Thermal-Image
KentixONE
LAN (PoE)
Radio (BLE)
Sysport (TYPE A)
- Integrated sensors: 9
- Monitored threats: up to 20
- 4-factor early fire detection
- Web server (HTTPS)
- E-MAIL - SNMP-V2/3 - REST-API
- LAN-RADIO (BLE) repeater integrated
The MultiSensor-TI is the latest MultiSensor technology with integrated thermal imaging sensor for monitoring critical system conditions and for early fire detection. In addition to pure thermal monitoring, the sensor can also detect the movement of people. Compared to thermal imaging cameras, the sensor has the advantage that it works in compliance with data protection regulations and intelligently links several sensors for early fire detection. For early fire detection, this means that up to four factors (thermal image, CO, air quality, room temperature) are analysed for reliable detection.The MultiSensor monitors up to 20 threats and an area of up to approx. 40m² depending on the ceiling height. It is connected via Ethernet with PoE (Power over Ethernet) and therefore requires no additional cabling. Operation is possible as a stand-alone sensor with integrated KentixONE software (HTTPS) or via a networked KentixONE system with SiteManager. The sensor is mounted on the ceiling using the mounting bracket supplied. Mounting in an IT rack or on the wall with the 19’ bracket (accessory) is also possible as an option.Detection angle: 90° or 40° (depending on type)Integrated sensors for monitoring: Temperature, air humidity, dew point, smouldering fire (CO), air quality, air pressure, movement, acceleration/vibration (G), two external alarm contacts.Alarm notification via MultiSensor (stand-alone): E-mail, SNMP traps (V2/3), web hooks (REsT-API)Alarm notification via SiteManager (central): SMS, PUSH (app)
Sale
Sale
€675.00
excl. VAT
MultiSensor-LAN with PoE (Black)
KentixONE
LAN (PoE)
Radio (BLE)
Sysport (TYPE A)
- Integrated sensors: 8
- Monitored threats: up to 19
- Web server (HTTPS)
- E-MAIL - SNMP-V2/3 - REST-API
- LAN-RADIO (BLE) repeater integrated
Network-compatible MultiSensor for complete room monitoring of up to 19 threats. Monitors an area of approx. 20-25m². The connection is made via Ethernet with PoE (Class 1) and therefore requires no additional cabling. Operation is possible as a stand-alone sensor with integrated KentixONE software (HTTPS) or via a networked KentixONE system with SiteManager. The sensor is mounted on the ceiling using the mounting bracket supplied. Optionally, it can also be mounted in an IT rack or on the wall using the 19’ bracket (accessory).Also ideal as an independent room sensor to supplement network monitoring systems (PRTG, Nagios, CheckMK, etc.) via SNMP-V2/3 or REST-API. The sensor can also send alarm e-mails in stand-alone mode.Integrated sensors: temperature, humidity, dew point, carbon monoxide sensor (CO), 360° PIR motion sensor, 3-axis G-sensor, digital input/outputs.
Sale
€525.00 excl. VAT
€525.00 excl. VAT
Digital I/O-Module with 16 digital inputs
LAN (PoE)
- 16 digital inputs (for dry contacts)
- connection of external alarm messages
- Integrated web server
- Ethernet 10/100MBit (PoE)
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..16 digital inputs for dry-contacts (e.g. air-conditioning, UPS system, external sensors, etc.)
4MP Compact Outdoor (IP66) Dome Network Camera
LAN (PoE)
IR-LED
- 4MP sensor with 2688×1520px
- Compact chassis with 109mm
- Super dynamic range 102dB
- IR LED integrated
- Color night vision (0.019 to 0.3 lx)
- H.265 smart encoding
- Corridor mode (90/270° image rotation)
4MP sensor, 2688×1520 pixels image with up to 30fps, Viewing angle H100°/V54°, Network 100Mbit (PoE) , Super dynamic range 102dB, Color night vision (0.019 to 0.3 lx), H.265 intelligent coding, Corridor mode (90 degree or 270 degree image rotation), Built-in IR LED, IP66 protection, NDDA compliant, ∅109x62mm, contetn of delivery: 5MP dome network camera (white).
Leakage sensor for detecting water and flooding
Sysport (TYPE A)
- Plug 'n Play connection
- Sensor sensitivity adjustable
- 5-fold cascadable
- Monitored for cable break
The leakage sensor is used to detect water leakage on the floor and is connected to an SiteManager or MultiSensor directly to the Kentix system port (TYP A). It continuously detects conductivity via multiple electrodes directly on the housing or additionally via a sensor cable.The sensor has an integrated point sensor with adjustable sensitivity. The versions with sensor cable (KLS03-ROPE-10/20) detect water in addition to the point sensor over the entire sensor cable length (10/20m). The sensitivity of the point sensor is 1-2ml water, the sensitivity of the sensor cable is approx. 10ml water over 20cm cable length.The leakage sensor can be cascaded up to 5 times and is therefore also suitable for large rooms.
MultiSensor-DOOR (Black) wireless and battery powered
Radio (BLE)
Battery
- Integrated sensors: 6
- Monitored threats: up to 10
- Wireless (BLE)
- Battery (approx. 4 years)
Ultra-compact MultiSensor for intrusion and status monitoring of doors and windows including ambient monitoring of temperature, humidity and dew point. The sensor is additionally equipped with a 3-axis G-sensor and detects vibration and position changes (sabotage detection, attempted break-in, glass breakage).The MultiSensor-DOOR replaces classic door contacts and can be mounted very easily by gluing or screwing it on. The supplied door/window magnet serves as a counterpart for secure opening detection.The MultiSensor-DOOR is battery operated and has a long battery life (up to four years). It is connected to an MultiSenor-LAN via radio (BLE).
Monitor room temperature
Monitor room temperature for high/low values to protect against heat damage or overheating of equipment.Server room environment monitoring according to basic protection (ISO27001)
Constant monitoring of the server room for temperature, humidity and intruders to ensure the smooth operation of the IT infrastructure.Monitor office space for burglary, fire, climate
Comprehensive monitoring of the office for movement, temperature and air quality to ensure safety and comfort.Monitor air quality (AIRQ, CO2) in rooms
Air quality monitoring to ensure a healthy indoor environment.Early Fire Detection for Battery-Accumulator Storage
Early detection of fires caused by fire gases or increased temperature in batteries to detect potential fires at an early stage.Early fire detection for IT and server rooms with environment monitoring
Early detection of fires caused by fire gases or increased temperature in the server room to protect sensitive IT infrastructure and data.Early fire detection for machine monitoring
Detection of fires or smoke development in machines to minimize production downtime and fire risks.Early fire detection in electrical distribution and transformer stations
Monitor electrical distribution for fires or thermal overload to prevent electrical damage or fires.Early fire detection for floor tea kitchens in office areas
Early detection of fires by smoke gases and surface temperature in the tea kitchen to prevent fire damage and safety in the workplace.Monitor heating failure and frost protection
Heating failure alarm prevents frost damage and protects sensitive equipment and devices.Delivery Contents
- 1x MultiSensor with Thermal-Image sensor
- 1x SlimLine cable 3m
- Mounting material