The MultiSensor-TI is the latest MultiSensor technology with integrated thermal imaging sensor for monitoring critical system conditions and for early fire detection. In addition to pure thermal monitoring, the sensor can also detect the movement of people. Compared to thermal imaging cameras, the sensor has the advantage that it works in compliance with data protection regulations and intelligently links several sensors for early fire detection. For early fire detection, this means that up to four factors (thermal image, CO, air quality, room temperature) are analysed for reliable detection.
The MultiSensor monitors up to 20 threats and an area of up to approx. 40m² depending on the ceiling height. It is connected via Ethernet with PoE (Power over Ethernet) and therefore requires no additional cabling. Operation is possible as a stand-alone sensor with integrated KentixONE software (HTTPS) or via a networked KentixONE system with SiteManager. The sensor is mounted on the ceiling using the mounting bracket supplied. Mounting in an IT rack or on the wall with the 19’ bracket (accessory) is also possible as an option.
- Detection angle: 90° or 40° (depending on type)
- Integrated sensors for monitoring: Temperature, air humidity, dew point, smouldering fire (CO), air quality, air pressure, movement, acceleration/vibration (G), two external alarm contacts.
- Alarm notification via MultiSensor (stand-alone): E-mail, SNMP traps (V2/3), web hooks (REsT-API)
- Alarm notification via SiteManager (central): SMS, PUSH (app)
Monitor room temperature
Monitor room temperature for high/low values to protect against heat damage or overheating of equipment.Server room environment monitoring according to basic protection (ISO27001)
Constant monitoring of the server room for temperature, humidity and intruders to ensure the smooth operation of the IT infrastructure.Monitor office space for burglary, fire, climate
Comprehensive monitoring of the office for movement, temperature and air quality to ensure safety and comfort.Monitor air quality (AIRQ, CO2) in rooms
Air quality monitoring to ensure a healthy indoor environment.Early Fire Detection for Battery-Accumulator Storage
Early detection of fires caused by fire gases or increased temperature in batteries to detect potential fires at an early stage.Early fire detection for IT and server rooms with environment monitoring
Early detection of fires caused by fire gases or increased temperature in the server room to protect sensitive IT infrastructure and data.Early fire detection for machine monitoring
Detection of fires or smoke development in machines to minimize production downtime and fire risks.Early fire detection in electrical distribution and transformer stations
Monitor electrical distribution for fires or thermal overload to prevent electrical damage or fires.Early fire detection for floor tea kitchens in office areas
Early detection of fires by smoke gases and surface temperature in the tea kitchen to prevent fire damage and safety in the workplace.Monitor heating failure and frost protection
Heating failure alarm prevents frost damage and protects sensitive equipment and devices.Delivery Contents
- 1x MultiSensor with Thermal-Image sensor
- 1x SlimLine cable 3m
- Mounting material