Skip to main content Skip to search Skip to main navigation

Sensors and actuators

In addition to the monitoring areas already covered by the MultiSensors, the ability to connect external sensors and actuators opens up a wide range of other applications. For example, external units such as air conditioning systems, mains fuse monitoring, UPS systems or general system fault messages can be connected. In the usual Kentix consistency, our external sensors are connected either plug 'n' play via the Kentix system socket (SYSPORT) or via external I/O modules with Ethernet and POE.

Of course, all modules are monitored by KentixONE to prevent failures or sabotage.

Network siren with ethernet (PoE)

NEW
Easy
Network-Siren (PoE) with RGB LED and buzzer
KentixONE LAN (PoE)
  • Network siren with RGB LED
  • Multi-tone buzzer up to 100 dB
  • As alarm and status indicator
  • Own KentixONE presets
  • Wall/ceiling mounting
Network alarm siren with PoEThe network-compatible alarm siren can be installed inside the building and in weather-protected outdoor areas. It is a combined signaling device and an essential component of a functioning alarm chain. In the event of an alarm, the siren generates a very loud, adjustable signal tone of up to 100 dB sound pressure. In addition to the acoustic alarm, a visual alarm is given by a colored, clearly visible LED light. It is connected and controlled via an Ethernet PoE network port (RJ45). Product detailsAlarm siren with Ethernet 10/100Mbit for indoor areas, PoE (Class 3), sound pressure: up to 100dB, various sounds adjustable, LED: red/green/blue, temperature range: -20 °C to +70 °C / max. 95%rh, non-condensing, connection: Ethernet RJ45 socket, function: LED colors (RGB) separately controllable, several sound signals to choose from, housing: ABS, IP43, weight: approx. 250g, size: Ø93 mm, H123 mm

Price after login

Log in or register now

Network alarm siren

The network-compatible alarm siren can be installed indoors and in weather-protected outdoor areas. It is a combined signaling device and an essential component of a functioning alarm chain. In the event of an alarm, the siren generates a very loud, multi-adjustable signal tone of up to 100 dB sound pressure. In addition to the acoustic alarm, a visual alarm is triggered by colored and mixable, highly visible LED light.
 KentixONE offers extensive configuration options. Customized information, alarm or warning statuses can be displayed visually and acoustically via configurable presets.
It is connected and controlled via an Ethernet PoE network connection (RJ45).

Water leakage sensor for Kentix systemport

Leakage sensor for Kentix system port (TYPE A) with 10m sensor cable
LAN (PoE)
  • Plug 'n Play connection
  • Sensor sensitivity adjustable
  • 5-fold cascadable
  • Monitored for cable break
The leakage sensor is used to detect water leaks on the floor and can be used either as a standalone device or integrated into KentixONE. It continuously measures conductivity via several electrodes directly on the housing and additionally via two 10/20 m long sensor cables.The leakage sensor has 3 separate sensors: One point sensor and two sensor cables that detect water over their entire length (10/20 m). The sensitivity of the point sensor is 1-2 ml of water, and that of the sensor cable is approx. 5 ml of water over a cable length of 10 cm.Supplied with new retaining clips for the sensor cable – no more drilling required.
Sensor cable

Price after login

Log in or register now

Available from February 2026

How does leakage monitoring work?

The Kentix leakage sensor is a conductive sensor that continuously measures conductivity via several electrodes. In addition, the leak sensor has two sensor cables (10 or 20 m) with integrated sensors that detect water ingress early on along the entire length of the sensor cable. Connection is via LAN PoE.

I/O expansion modules for external alarms with Ethernet (PoE)

Digital I/O-Module with 16 digital inputs
LAN (PoE)
  • 16 digital inputs (for dry contacts)
  • connection of external alarm messages
  • Integrated web server
  • Ethernet 10/100MBit (PoE)
The I/O expansion module connects to an AlarmManager/SiteManager and is used to connect external alarm messages. The communication takes place via Ethernet. Thus, the module can be mounted at any location. The configuration is done in the KentixONE..16 digital inputs for dry-contacts (e.g. air-conditioning, UPS system, external sensors, etc.)
Variation

Price after login

Log in or register now

I/O expansion modules

The I/O extension modules are used to connect external fault messages via electrical transfer contacts. For example, alarm messages from external systems such as generators, UPS systems, air conditioning systems, etc. can be easily integrated and monitored.

The I/O expansion modules are integrated into KentixONE via Ethernet and the power is supplied via PoE. This means that the modules can be installed anywhere in the network. The configuration is carried out via KentixONE. The module offers a simple basic IP configuration via the integrated web server and the option of testing the inputs/outputs without additional software.

When selecting the I/O modules, the different input signals must be taken into account. In 80% of applications, so-called "potential-free contacts" are connected. These are pure transfer contacts without voltage potential. The I/O module with 16 digital inputs (ART: KIO7053) is the ideal and most common solution for this. However, live connections with 12-50VDC or analogue signals with 0-10VDC or 4-20mA can also be integrated with the corresponding modules.

Accessories for the I/O expansion modules

Temperature sensor IP66 (-50 to + 100 ° C) for KIO7017
  • Temperature sensor Pt1000 class B
  • 3 selectable temperature ranges
  • Protection class IP66
  • Integrated sensor
PT1000 class B outdoor temperature sensor with active current (4-20mA) and voltage output (0-10V).Three selectable temperature ranges (-50°C ... + 50°C; 0°C ... + 50°C; 0°C ... +100°C).Housing protection IP66.Power supply 24VDC/4mA.For connection to I/O module KIO7017.
Design

Price after login

Log in or register now
Magnet Door-Contact, white, 2m cable
Door contact with open cable. Contact: NO, cable lenght 2 m, color: white, Size: (L x H x W) 11 x 12 x 48 mm, Delivery: Magnet-contact with mounting material

Price after login

Log in or register now
19-Inch 4U Mounting Frame with DIN-Rail 35mm
19" mounting frame with 4U for mounting up to 22 modules (Division Units) on DIN rail (35mm), height: 176mm, material: sheet metal 2mm, scope of delivery: 19" frame

Price after login

Log in or register now